Parameters

With the exception of modifications for full-structure data sets having a resolution lower than 1.1Å (section 6 below) the following recommended parameter settings (as of this release) are built into the program as default values. A current list of parameter recommendations is maintained on the SnB web site. Several parameter values are dependent on "Nu", the number of unique non-H atoms in the asymmetric unit. In the case of solvated molecules, it is generally not critical whether the solvent atoms are counted when determining Nu. In the case of SIR or SAS substructures, Nu is the number of heavy atoms or anomalous scatterers.

  1. Normalization Parameters

  2. Phase Refinement Parameters

  3. Dual-Space Fourier Parameters

  4. Twice Baking (E-Fourier Recycling) Parameters

  5. Trials & Cycles

  6. Using SnB at 1.1-1.2Å
    Note: These changes are not made automatically

  7. SnB for Substructures (Nu = number of heavy atoms or anomalous scatterers)