PLUTON - MANUAL
1.0 - INTRODUCTION TO PLUTON
PLUTON is an easy-to-use interactive graphics program. It can be used
as a tool for viewing, analysis and presentation of molecular
structures. Drawings of either individual molecules or assemblies of
molecules in a crystalline arrangement can be produced. Coordinate
input data can be either Cartesian or fractional, originating from
crystal structure determination programs such as SHELXS, refinement
programs such as SHELXL or otherwise.
PLUTON may be considered as a completely redesigned and considerably
expanded variety of the popular program PLUTO(78) by Motherwell and
Clegg. Drawings are produced either on a display surface (graphics
terminal or workstation) called DISPLAY or as a meta-file saving
graphics instructions (called META) for later use such inclusion in
word processors (e.g. Word) or laser printer hardcopy, suitable for
publication.
PLUTON is currently available only as a build-in link into the PLATON
suite of programs.
Program versions are available for various platforms including
DEC-UNIX, SiliconGraphics, IBM RISC/6000, VAX/VMS (including and on
IBM-PC's or compatibles under MS-DOS. Several graphics devices are
supported ranging from simple tektronix 4010 terminals/emulators to
X-Window graphics devices.
A drawing of a molecular structure as generated by PLUTON may be
thought of in three principle aspects: the content, the style and the
viewpoint. The content of the drawing requires the definition of items
such as ARU's (= asymmetric residue units, vide infra) making up the
list of molecules and anions to be displayed, atoms within ARU's,
connections between atoms (= bonds), labels, and unit cell
representation. By default, connected and possibly symmetry expanded
sets of atoms constituting molecules or ions will be assembled. The
style of the drawing may be like a STICK model (atoms are points and
bonds are single lines joining them), a SOLID ball-and-spoke,
ball-and-STRAW or ball-and-ROD model, mainly differing in the default
settings of the variable radii for atoms and bonds, or a space filling
model with van der Waals radii assigned to each atom (also called CPK
model). The atom types may be distinguished with various patterns in
the black-and-white mode or colored to differentiate between the atom
types. Drawings may be made in parallel projection, perspective, or
stereo-pair perspective. By default, a STICK-style drawing will be
generated. The view direction may be chosen with reference to molecular
features such as lines and planes defined by atoms, or with reference
to the unit cell or orthogonal axial systems. The view direction may be
further modified by rotations, giving flexible control of the
viewpoint. By default a minimum overlap view is choosen.
All input to the program is free-format, using (sub)keywords and
numerical data. The input to PLUTON is normally provided in two parts:
a disk file, in general produced by a program or prepared with a text
editor and containing the pertinent data on the structure at hand such
as atomic coordinates, followed by interactive input of the
instructions via the keyboard. In general, a small set of instructions
in terms of global keywords with associated default parameter settings
will suffice to produce a drawing for the set of supplied atomic
coordinates. Alternatively, all input may be given on the disk file or
interactively from the keyboard.
More than one data set, separated by an ENDS card may be present on the
disk file. This is a convenient feature for browsing the structures
retrieved from the Cambridge Structural Database. In that case, an
interactively supplied END statement will not stop program execution
but load the next data set (use the instruction STOP for premature
abortion). Facilities are available (the SAVE instruction) to run the
same set of instructions on a file that contains more than one data set
(e.g. a series of structures extracted from the Cambridge Structural
Database).
Note: PLUTON is not a finished program. It is extended and improved
constantly on the basis of the needs that arise as part of our research
work, including many hundreds of crystal structure determinations
(organic, organometallic and inorganic) carried out as part of a
national crystallographic service. New features are planned. Therefore
there may be some discrepancies between the actual program and this
manual. It is advised to consult the on- line manual (available with
the HELP ALL feature of the program) for the most current list of
instructions.
Suggestions for improvement or information on errors are welcome.
Availability: The program is available free of charge from the author
for use within the academic community under the condition that it is
not redistributed. A licence fee is charged to profit organizations.
2.0 - INTRODUCTORY EXAMPLE
The following example, assumed to run on a unix system, of the
structure of CYTOSINE should provide a simple introduction to the use
of the program and its potential.
A Tektronix emulator or the X-Window menu-off mode is assumed here.
X-Window based implementations support both keyboard instructions and
menu driven input with ain automatic redraw of an updated image.
The structural parameters are assumed to reside on a disk file, named cyto.spf
in this example, for which the contents are listed below (free
format). This particular input format is convenient for viewing
structures with parameters taken from a publication:
TITL CYTOSINE (ANHYDROUS) ACTA CRYST. B29, 1234, 1973.
CELL 13.044 9.495 3.814 90 90 90
SPGR P212121
N1 0.0222 0.0285 0.4410
C2 -.0164 0.1561 0.3276
O2 -.0998 0.1595 0.1710
N3 0.0402 0.2745 0.3877
C4 0.1308 0.2635 0.5492
N4 0.1842 0.3828 0.5967
C5 0.1705 0.1337 0.6674
C6 0.1134 0.0187 0.6084
H1 -.013 -.057 0.363
H3 0.154 0.463 0.541
H4 0.248 0.378 0.652
H5 0.237 0.128 0.796
H6 0.132 -.078 0.692
PLUTON may be invoked for this data set with the command:
pluton cyto.spf
As a result the data set CYTO is loaded and, since this file does not
contain an END instruction at the end of the file, the program comes,
after that the end-of-file has been reached on this file, with the
prompt >>, ready to receive additional data and/or instructions
interactively.
When we now type in respons to the prompt the instruction PLOT, the
program will automatically assemble a unique molecule (i.e. symmetry
operations will be applied when necessary to find connected sets of
atoms), find all bonds and generate a minimum overlap stick-style plot
of the structure (Fig. 1), optionally
followed by a bell signal on completion of the plot. The program now
waits for the user to press the RETURN (or ENTER) key to present the
prompt >> again and to accept new instructions. Alternatively, a
new instruction may be typed directly without waiting for the prompt.
At this point the automatic minimum overlap view direction may be
modified with any of the available VIEW instructions. As an example we
can rotate the structure clockwise by 45 degrees about the horizontal
X-axis with the instruction VIEW CURRENT XROT 45 (or to the same effect
XROT 45) and see the effect with a new PLOT instruction. The style of
the plot may be changed into the SOLID, STRAW, ROD or CPK style with
corresponding instructions: e.g. ROD SHADE COLOR followed by PLOT ( Fig. 2) or CPK GLOBE COLOR followed by
PLOT (Fig. 3).
A PLUTON session thus involves a series of cycles, each of which
consisting of contents, style and viewpoint modification instructions,
if any, followed by a PLOT instruction. As an aid, it is possible to
inspect the contents of the various internal tables with instructions
such as LIST ATOMS, LIST BONDS or LIST ARU. On- line information on the
available instructions is available by typing HELP. A status line
reports the current values on some of the more relevant settings. Use
HELP GRAPHICS for instructions to change the default graphics settings.
The input set of fractional coordinates is not required to form a
connected set or even a complete molecule in case of molecules sitting
on a crystallographic symmetry element. Unless instructed explicitly by
the user, the necessarily calculations are carried out automatically as
communicated to the user by the expression AEX:: JOIN RADII UNIQUE
EXPAND. This will automatically generate a connected set based on
standard covalent radii and symmetry expanded when applicable. Where
appropriate the user is informed about problems, new parameter values
and the current status of relevant parameters.
Intermolecular hydrogen bonds of the type Donor-H...Acceptor may now be
generated with the instruction:
JOIN HBONDS
An alternative would be
JOIN RADII INTER H 1.2 O 1.5 N 1.5
but this will generate many unwanted additional contacts that will have
to be deleted subsequently from the bond list). The list options (e.g.
LIST ATOM, LIST BONDS or LIST ARU) may be used following this
instruction to verify that several items were added to the atom, bond
and aru lists.
A SOLID type packing diagram with the unit cell outline and viewed down
the c-axis of the structure is generated with a few additional
instructions (Fig. 4):
SOLID
PACK RANGE -0.5 1.5 -0.5 1.5 0 1
UNITCELL
VIEW ZO
PLOT
To finish the program the instruction END should be issued. The trailer
listing file provides a detailed log of the current session. All
instructions are saved on a journal file to reconstruct previous style
and orientation settings. In addition the name of the generated meta
file (if any) is given.
3.0 - ON HOW IT WORKS
This section on program internals should provide a framework to
understand most of the effects of the available instructions.
The input atomic coordinates (x, y, z) are with reference to user-
defined axes (a, b, c), which will usually be either crystallographic
unit cell axes or an arbitrary orthogonal set; these coordinates are
input as fractions of the unit cell edges or as Angstrom units (in the
latter case they are converted to and stored internally as fractions of
dummy cell edges). A second, orthogonal system (A, B, C) (see J.D.
Dunitz, X-Ray analysis and the Structure of Organic Molecules, Cornell
University Press, p235) with coordinates (XO,YO,ZO) in Angstroms is set
up internally: The unit vector A is choosen along a, B as unit vector
normal to a in the ab plane, and C normal to A and B. This orthogonal
system is coincident with the first system when the input axes are
orthogonal. The third system is the plotting coordinate system in cm:
XP across the picture from left to right, YP up the picture from bottom
to top and ZP out of the paper. All these axial sets are right-handed
and absolute configuration is preserved in all rotations.
As atoms are input to the program, they are stored both in the X, Y, Z
and the XO, YO, ZO coordinate system. The XP, YP, ZP system is used
only when plotting is actually being performed. Each atom has
additional information stored for it including the atom name (the
embedded element name is used by default to set various radii) and
various flags such as for inclusion in the plot and labelling. This
data structure is known as the atom list. Duplicate entries with the
same coordinates are skipped from the input stream.
The JOIN instructions (either by default or as specified) set up a list
of connections (known as bond list) between atoms. Each connection is
simply a pair of atom serial numbers referring to the input atom list.
Some JOIN instructions also find connections between input atoms and
other atoms related to the original list by crystallographic symmetry.
This may include both connections to a symmetry related part of a
molecule sitting on a special position or intermolecular connections.
In order to store these connections for plotting, the program appends
dummy symmetry-generated atoms to the atom list and marks them with a
special flag.
If the final picture is to contain several molecules, as in a packing
diagram, or a complete molecule for which the input atoms represent
only the symmetry-independent portion of it when a molecule lies in a
crystallographically special position in the unit cell, the program
will have to generate XP, YP, ZP coordinates for the atoms in each of
these molecules or symmetry-related molecular fragments. This is
controlled by two further lists: a list of symmetry operations
pertaining to the structure, input directly using the SPGR or LATT and
SYMM instructions; and a list of 'molecules and ions' (known as ARU
list) to be drawn (see discussion on ARU & ASU below).
The program works as follows. Instructions (free format) are read and
interpreted. Various instructions add to the list of atoms and symmetry
operators. The JOIN instructions set up the connections list and may
also add to the atom and ARU-lists if connections between ARU's are to
be generated. Plotting parameters are then set by user instructions or
left at default settings. No plotting is actually done until the PLOT
instruction is read. This first sets up the XP, YP, ZP plotting list of
all atoms to be plotted. The information in the ARU list and the
current view matrix together tell the program how to convert X, Y, Z
into XP, YP, ZP. The plotting coordinates and atom radii are scaled
from Angstroms to cm. and corrected for perspective if requested. In
the non-stick mode, all atoms in the plotting list are drawn, allowing
for obscuring of some by others and bonds, and intersection of spheres
in space-filling models and bonds in the ROD mode, except that dummy
atoms are not usually drawn - they are required only so that
connections between molecules are possible, and will generally be
duplicated by other non-dummy atoms generated in the XP, YP, ZP list by
symmetry from the original input atoms. Following the atoms, all the
bonds are drawn, omitting portions obscured by atoms or bonds. Atoms
are labelled by a routine which minimises overlap of the labels by
atoms, bonds and other labels. When the picture is complete, the next
instruction may be read.
Most data are stacked in a large array, either bottom-up or top down,
so that the stack size is the limiting factor for the size of the
problem that the program can handle. The program reports on the maximum
memory usage in the current run. The stack size is a program
implementation parameter.
The input list of atoms is checked on redundancy.
DATA and INSTRUCTION FILES
The order in which data are read is as follows:
-
The primary datafile (e.g. sucrose.spf) is read. When an EOF or ENDS
line is encountered:
-
A file named sucrose.def (when present) is read.
-
Saved Instructions are read
-
Instructions from the keyboard or Mouse-clicks are processed
4.0 - Terms and Notions.
Connected sets of atoms are assembled in the following way. The
procedure is started by first fixing a suitable atom. Next symmetry
operations are performed on all atoms in the input set to find atoms
that are connected to it. Atoms that are found to be connected are
fixed as well and used to fix yet other, possibly symmetry transformed,
atoms bonded to them as well. This procedure continues until no new
bonded atoms are found. In the simple case of one chemical unit per
asymmetric unit this constitutes an object named a molecule and is
denoted with the identity code 1555. Symmetry related molecules are
denoted by the general code sklm, where s is the number of the symmetry
operation of the space group and k,l and m translation components.
Chemical units may extend over more than one asymmetric unit. They may
have a symmetry element that coincides with the space group symmetry
such as an inversion centre or a screw axis. In such cases we will find
atoms in the above search for a connected set of atoms that are bonded
to the connected set at a position different from the one that was
fixed in view of an earlier connection. Those atoms are added to the
connected set and marked as symmetry related. The symmetry operation of
this atom with respect to the primary one is coded and added to the
molecule (aru) list. A chemical unit around an inversion centre thus
consists in the PLUTO78 terminology of two molecules: 1555 and 2555. A
further complication may be the presence of more than one
crystallographically independent chemical unit in the unit cell
(including solvent molecules and anions). In that case not all atoms
will be fixed when the above procedure comes to an end when no more
connected atoms are found. In that case a new residue is started by
again arbitrarily fixing a suitable atom and expanding it to a
connected set. A particular residue r within a molecule is indicated
with the code sklm.r (e.g. 3564.03). It is understood that the code
without a fraction stands for the full collection of residues. Thus in
the case of two residues the molecule code 2562 is equivalent with the
two residue codes 2562.01 and 2562.02. In order to be more precise two
new terms have been introduced in PLUTON and PLATON. The basic
structural unit is the asymmetric residue unit ( = aru ) coded as
sklm.r. A molecule (ion) will will be an assembly of at least one aru.
The set of aru's making up the asymmetric structural unit are called
asu and encoded as sklm.
Disorder. Based on the supplied population parameters attemps are made
to suppress bonds between disorder parts with unequal population
parameter values.
5.0 - PLUTON INSTRUCTION SUMMARY
The order of data input and instructions is fairly flexible. However,
CELL, SPGR (or LATT and SYMM) or ANGSTROM data, if any, and atomic
coordinate data should preceed any PLOT or qualifier instruction. CELL
and SPGR (or LATT and SYMM) must come before ATOM. The order and number
of content, style and viewpoint instructions is completely flexible,
except for that all desired parameter values must be set before the
next PLOT instruction. An interactive graphics session will consist of
a repeated cycle of qualifier and PLOT instructions. The END line is
the last instruction and may be used to finish the plot session in an
orderly fashion (see also STOP and QUIT).
By using the default settings associated with the choosen plot style
(e.g. ROD) only a few of the available instruction types are absolutely
required to produce a preliminary drawing of a structure. The absolute
minimum input is a set of Angstrom coordinates, a PLOT instruction and
END to stop the program.
In the description of individual instructions below the following
applies:
-
(Sub)keywords are in uppercase and user data in lower case.
-
Data in parentheses are optional.
-
Choices are separated by a slash.
-
Values in [] are default settings
-
Parentheses in atom names (on input) are ignored except for that Ag
denotes the atom type and Ag() the individual atom in cases where no
numerical part is associated with the label.
-
Lowercase input is automatically converted into uppercase characters
except for the content of the TITL line that is left as is.
ANGLE atom-name1 atom-name2 atom-name3
The angle between the three specified atoms with
atom-name2 as apex is calculated. The three atoms are not necessarily
bonded atoms, but should be present in the current atom list. This list
can be inspected with a LIST ATOMS instruction. An individual angle may
be calculated as an aid in the analysis of the geometry of the
structure. Exhaustive geometry listings may be obtained with the
companion program PLATON. (See olso the GEOM instruction)
Example: ANGLE C(2) O2 N(2)
ANGSTROM (scale [1.000])
The following data are in orthogonal Angstrom units
after multiplication with 'scale'.
The 'scale' should be adequate riIn order to fit in the
automatic connectivity search based on the build-in covalent radii.
ARU (color) (aru1 (aru2 ..) (resd)
This instruction adds in a cumulative fashion asymmetric
residue units (aru's) to the list of aru's to be drawn. It allows the
user to have direct control over the list of residues to be drawn. This
instruction is needed only when the automatic maintenance of this list
with the JOIN RADII and/or PACK instructions is found to be not
adequate. The ARU list may be inspected with the LIST ARU instruction.
ARU's (e.g. aru1) are designated by a composite number (ARU) that may
be split up into five parts: ARU = S*1000 + TX*100 + TY*10 + TZ + 555 +
R*0.01, where S is the serial number of the symmetry operator (from the
complete list to be inspected with a LIST SYMM instruction) to be
applied to the input list of coordinates; TX, TY, TZ are the unit cell
translations and R is the residue number. A negative sign of ARU means
that the specified residue should not be drawn in the following plots,
and may be used to eliminate residues temporarily from the list of
residues to be plotted. This may useful in conjunction with the pack
instruction.
Often residue numbers are not explicitly indicated and
the fractional part of ARU effectively set to zero. In this form the
complete asymmetric structure unit (ASU) is meant.
Examples: ARU 3555 7564 -1555 ARU 3564.01
Note: for packing reasons, the number of residues that
can be coded is restricted to 9 with corresponding change in aru
coding.
ARU NONE/UNIQUE/INTER/RESTORE
The effective ARU list is emptied with the NONE
sub-keyword. (A LIST ARU will show that all ARU's now have negative
values). The list is reset to what it was after a previous JOIN RADII
UNIQUE or INTER instruction with the UNIQUE or INTER keywords
respectively. A RESTORE sub-keyword resets all negative entries in the
molecule list to their absolute value, so that they are active again.
If the effective ARU list is empty when the PLOT
instruction is read, a ARU 1555 instruction will be executed
automatically.
Example: ARU NONE
BOX (ON/OFF[ON]) (SHRINK shr[90]) (RATIO ratio[1.333])
By default the drawing will be surrounded with a
rectangular box outline. This setting may be changed with the ON and
OFF sub- keywords. The structure is drawn with a shrinkage factor of 90
percent relative to the automatic scale factor that fits the drawing
within the BOX-outline to provide a margin. This default percentage may
be changed with the SHRINK shr option. This option may be also of use
when a drawing which a non-default scale is required. The three numbers
shown in the bottom right, top left and bottom left corner of the box
are the cumulative rotation angles xr, yr and zr respectively. These
numbers may be used to reconstruct this particular orientation in a
later session directly from the default UNIT orientation via a VIEW
UNIT XR xr YR yr ZR zr instruction. The default horizontal to vertical
size ratio of the box is 4/3. A ratio of 1.0 results in a square box.
Example: BOX RATIO 2 SHRINK 80
BWC TYPE atom-type bwc (atom-type bwc ...)
An alternative to color coding of atom types is a
distinction of atom types with different patterns drawn on the spheres
representing the atoms. This is useful for black-and-white hardcopy and
publication drawings. The current (default) settings may be inspected
with the LIST TYPES instruction. Available options for bwc are contour,
net, shade, segment, dots, black, cross, parallel, globe, meridian,
horizontal, vertical, mesh, diagonal, slant, textile and void.
Example: BWC Pd GLOBE
BWC (ON/OFF)
BWC ON/OFF toggle.
COLOR BLACK/RED/GREEN/BLUE/YELLOW/ORANGE/VIOLET/BROWN
This instruction may be used to change the default
colour (normally BLACK for plotters and WHITE for terminal screens) of
the plot into the one chosen (subject to the availability of colour
with the actual graphics facility). This colour is used for bonds, atom
circumference and text.
Example: COLOUR RED
COLOR TYPE atom-type col (atom-type col (...)
The color setting of an atom-type, as shown with a LIST
TYPES instruction, may be modified with the COLOR TYPE instruction. The
color code is a two-digit number, one digit for the color to be used
for the odd-numbered lines and one digit for the even-numbered lines. 0
= blanc, 1 = black(white), 2 = red, 3 = green and 4 = blue. E.g. a red
oxygen atom has code 22. By default the lines are drawn horizontally.
The general color format is nnmmeo with e and o the colour numbers for
the even and odd lines respectively, mm the clockwise rotation angle
for the odd lines and nn the anti- clockwise rotation angle for the
even lines relative to the odd lines:e.g. 904522.
Example: COLOR TYPE C 01 O 22
COLOR RESD (ON/OFF)
On/off toggle for display of residue colors.
COLOR ARU (ON/OFF)
On/off toggle for color per ARU.
COLOR (ON/OFF)
Color on/off toggle.
COORD atom-name
List geometry about 'atom-name'
CPK (SHADE (a1 a2 (d))/COLOR (a1 a2 (d))/NET (nh
nv)/CONTOUR/ SEGMENT/BLACK/BWCOL/DOTS/GLOBE /CROSS/PARAL/MERID) (STICK)
(SPOT)
This sets parameters for a space-filling model
(Corey-Pauling- Koltum) with atomic radii that are taken by default
from internal tables and optionally with RADII ATOMS instructions. The
surface may be either globally Shaded, Coloured, Dotted, drawn with
Contours, segments, a Net structure etc. or with a pattern dependent on
the atom type (BWCOL). The keyword SHADE causes the drawing of shade
lines representing shadow from a light source whose position is given
by the two angles a1 and a2. The setting of both angles to zero models
a light source coming directly towards the viewer along the ZP axis, so
that the whole atom is shaded. The angles a1 and a2 are rotations of
the light source about YP and ZP respectively and in that order, and d
is the spacing in cm between shading lines. Default settings are 120,
-45, 0.15.
The atoms may be coloured as a function of their atom
type. This feature is implemented as the SHADE option with a1=a2=0 and
d = 0.05 in the absence of other sub-keywords with the COLOR sub-
keyword.
The NET sub-keyword produces a NET with two sets of
perpendicular great-circles drawn on the surface (colored in
combination with the COLOR sub-keyword). the number of horizontal and
vertical circles may be modified with nh and nv.
The GLOBE sub-keyword produces a polar grid surface,
combined with shading.
The CONTOUR sub-keyword produces a set of parallel
circles on the surface.
The BWCOL sub-keyword may be used to differentiate
between atom types in a black-and-white plot.
The SPOT sub-keyword asks for a light reflexion spot on
the surface.
The STICK keyword produces a CPK plot combined with a
STICK frame to show the chemistry of the molecule.
Example: CPK NET COLOR SPOT
Note: CPK COLOUR DOTS will generate white dots on the
colored atomic spheres.
CROT(X/Y/Z)(M) (COLOR [off]) (step [3.0] (nstep
[100000]))
CROTX will produce a stick model rotating about the
horizontal X- axis. CROTYM gives a model rotation about y,
anti-clockwise). Bonds may be colored as a functions of the atomtypes
at their end-points with the COLOR sub-keyword.
Example: CROTX COLOR
DETACH atom-name/atom-type (TO) atom-name/atom-type
This instruction allows the elimination of bonds from
the bond list, such as those resulting from intermolecular contact
searches or between non-bonded metals.
Example: DETACH CA C
DEFINE Me# TO atom-name1 atom-name2 (...)
Replace set of bonds by one bond to the centre of
gravity of the specified atoms. This is particularly useful to
represent the eta-5 bond of a metal to a cyclopentadienyl ring:
Example: DEFINE Ti TO C1 C2 C3 C4 C5
DELETE atomtype/atom-name .../aru
Delete specified items.
DIST atom-name1 atom-name2 (aru)
The distance between the specified and not necessarily
bonded atoms is calculated. Both atoms should be in the current atom
list (to be checked with a LIST ATOMS instruction) or explicitly
generated using the optional aru designator.
Example: DIST C1 C3 DIST C1 C3 2555.01
END/ENDS
End of plot instructions for this data set. The next
data set following an ENDS card is loaded when the SPF-file contains
multiple data sets. The program terminates when no data are left;
information on the produced files will be shown. Direct termination is
achieved with QUIT or STOP instructions.
ENTRY (nr/refcode)
Instruction to manage multi-entry data sets (e.g. from
CSD).
EXCLUDE
atom-names/atom-types/ALL/NONE/ORIG/UNIQUE/INTER
Exclude the specified atoms from the atom list. ORIG
means all the atoms originally input; UNIQUE means atoms generated by
JOIN RADII UNIQUE; INTER means atoms generated by JOIN RADII INTER.
Bonds are only drawn between included atoms, except that bonds to
UNIQUE and INTER atoms are drawn even if these atoms are omitted.
Usually, generated atoms need not be specifically included because they
duplicate original atoms in generated molecules. The effect of
successive INCLUDE and EXCLUDE instructions is cumulative. INCLUDE ALL
and EXCLUDE NONE are synonymous; so are INCLUDE NONE and EXCLUDE ALL.
The default is INCLUDE ALL.
Example: EXCLUDE H
GEOM atom-name
Interactive calculation of geometry around atom, i.e
bond distances and bond angles.
HELP
(ALL/BOX/BWC/COLOUR/DATA/GEOMETRY/GRAPHICS/INCLUDE/JOIN/
LABEL/LIMITS/LIST/MOLES/PLOT/RADII/SEGMENT/SIZE/ STYLE/SPGR/VIEW)
This gives on-line help on the specified type of
instructions. In particular HELP GRAPHICS will inform on the way the
graphics is implemented. HELP SPGR gives a listing of all the space
group names known to the program. HELP ALL gives the full list of
available instructions.
Example: HELP STYLE
INCLUDE atom-names/atom-types/ALL/NONE/ORIG/*/&
Include the specified atoms in the atom list. See
EXCLUDE.
INORG
Instruction modifies defaults to suitable values for
inorganic compounds.
JOIN (RADII (UNIQUE (EXPAND)) (NOMOVE) (TOLE
tole[0.7]) (TOL tol[0.2])/(atom-type1 r1 atom-type2 r2 ...))
A PLOT instruction that, since the start of the program
or after a RESET, was not preceded by any JOIN instruction will
automatically invoke the execution of a JOIN RADII UNIQUE EXPAND
instruction. This automatically produces a list of connections, an
ARU-list and an atom list for the possibly symmetrical molecule(s) in
the structure, based on internal covalent atomic radii. All distances
between two, possibly symmetry transformed, atoms less than the sum of
the covalent radii for the two atoms plus a tolerance (by default tol =
0.2 Angstrom per atom) will be entered in the connection list and
related changes or additions are made to the molecule and atom lists.
Atoms are moved (unless NOMOVE disables it to do so) to
symmetry-equivalent positions in order to form connected fragments. If
the molecule has symmetry coincident with space group symmetry
operators and only the asymmetric coordinate set supplied, the program
will look for connections between the symmetry-related portions of the
molecule. This involves the generation of dummy atoms and modification
of the molecule list as well so that the PLOT instruction will show the
complete molecule. The radii used for the automatic JOIN instruction
can be inspected with the LIST TYPES instruction. The user may override
this automatic feature by explicitly specifying the required JOIN
instruction(s) before the first PLOT instruction. When the EXPAND
sub-keyword is left out the molecules will not be fully symmetry
expanded as is needed for molecules exceeding threefold site symmetry.
Symmetry is not taken into account when in addition to this the UNIQUE
sub-keyword is left out so that the user is held responsible to provide
the correct set of atomic coordinates assumed to be already in bonding
distance. Also the atomic radii used may be changed by their explicit
specification:
JOIN RADII C 0.85 BR 1.35 H 0.4
This will find all C-C bonds less than 1.7, C-H less
than 1.25 and C-Br less than 2.2 Angstrom. Tolerance values are not
added to explicitly specified radii.
The ARU list is reset to the input set before entering
the connection search routine when a JOIN RADII instruction is read and
the connection list is also emptied.
The TOL sub-keyword may be used to change the value of
tol to be used along with the radii drawn from the internal tables (see
Appendix V). The single keyword instruction JOIN is equivalent with the
expanded form JOIN RADII UNIQUE EXPAND.
When appropriate an additional 0.7 Angstrom is added to
the tolerance value in the automatic radii mode to catch (earth-)
alkali to non-metal contacts.
JOIN RADII INTER (HBONDS) (EXPAND) (TOL tol)/
(atom-type1 r1 atom-type2 r2 ..)
To generate intermolecular connections (e.g. Hydrogen
bonds), the keyword INTER must follow RADII. This also involves
generating dummy atoms and modifying the molecule list so that a
subsequent plot will show several molecules unless the list is changed
by a MOLES or PACK instruction.
Example: JOIN RADII INTER N 1.5
would form the unique molecule first and then find all
potential hydrogen bonding interactions between nitrogen atoms less
than 3 Angstrom. Alternatively, the sub-keyword HBONDS may be used for
which only H to acceptor contacts are generated:
JOIN RADII INTER HBONDS
For JOIN RADII INTER, the molecule list is reset to the
list generated by a previous JOIN RADII UNIQUE; the connection list
remains at the current setting and the intermolecular connections are
added to the list as they are found.
When no explicit radii are given on a JOIN RADII INTER
card the program will use radii equal to the covalent radii + 0.8 +
tol. When only part of the inter radii is specified it is implied that
the radii for the remaining atom types is to be set to zero. The
instruction JOIN HBONDS is equivalent to the expanded form JOIN RADII
INTER HBONDS.
JOIN atom-name TO atom-names (aru)
The first atom on the JOIN card is joined to each of the
others.
Example: JOIN Mn1 TO C1 C2 C3 C4
JOIN atom-names/atom-types
This instruction sets up connections explicitly, adding
them to those already existing. Each atom is to be joined to the one
preceding it and the one following it in the list. Thus to draw a
benzene ring with atoms C1, C2, C3, C4, C5 and C6: JOIN C1 C2 C3 C4 C5
C6 C1
JOIN NONE/INTRA
A JOIN INTRA instruction deletes intermolecular
connections (those generated by JOIN RADII INTER), leaving only
intramolecular bonds, including those between symmetry-related parts of
a molecule (generated by JOIN RADII UNIQUE).
JOIN NONE empties the connection list.
LABEL atom-name1 (aru) (atom-name2 (aru)
(...))/atom-type1 (aru)..
The specified atoms are added to the current list of
atoms to be labelled. The program tries to find a suitable position for
the label close to the atom giving minimum overlap by other plot items.
The sub-keyword MOLES causes the symmetry code of the molecules to be
plotted against the first atom of each molecule.
Examples:
LABEL Cu N O
LABEL C1 C2 C3 N4 C5
LABEL ARU
LABEL ALL
UNLABEL *
The effect of successive LABEL instructions is
cumulative.
LABEL (ON/OFF) (ALL/NONE) (ATOMS) (ARU) (UNITCELL)
((NO)PARENTHESES) (FULL/NUM)
These label instructions are global. The ALL
sub-keyword gives labelling of all atoms and is undone with UNLABEL
ALL. ON and OFF have the same effect. Atom labels may be plotted with
or without (default) parentheses.
LIST/INFO (ATOMS) (BONDS) (LINES) (MATR) (ARU)
(STATUS) (TYPES) (GRAPHICS)
This causes some of the lists held by the program to be
displayed for inspection. The same lists are sent automatically to the
trailer output file when a PLOT instruction is executed.
The ATOMS option gives a list of the input atoms
together with any dummy atoms generated by a JOIN instruction. For each
atom, the coordinates and atom radius are shown, together with flags to
show whether the atoms are currently included and/or to be labelled.
BONDS list all the (active) connections currently held
with their distance and plot style parameters.
LINES lists the information set up by RADII BONDS
instructions.
MATR gives the current orientation matrix and the three
decomposition angles to reconstruct this orientation with a VIEW UNIT
XROT xr YROT yr ZROT zr instruction.
ARU gives the list of molecules.
STATUS list various parameter settings and other
relevant data.
SYMM gives a list of all equivalent positions, preceded
by their internal sequence number that is used in conjunction with the
ARU instruction.
TYPES gives a listing of all atom-type dependent
setting such as radii and colours. If none of the above keywords is
given, all the information is shown.
Example: LIST ATOMS BONDS
LIST ATOM (atom-name/atom-type/INTER)/(RESD resdnr)
This lists atom data from the atom list for the
specified atom or atom-type.
Example: LIST ATOM O
LIST BOND (atom-name1/atom-type
atom-name2/atom-type/INTER)/ (RESD resdnr)
This lists bond data for the specified bond from the
bond list.
Example: LIST BOND C3 C4
LIST CELL
This displays the current cell parameters for
inspection.
LIST SYMM
List symmetry operations and related data.
LIST PAR (nr1 (nr2))
Option to list an internal parameter value held in the
PAR list. A range is listed when two numbers have been specified or the
full list is case that none was specified. New values may be assigned
with the SET PAR instruction.
Example: LIST PAR 5
LIST IPR (nr1 (nr2))
Option to list an internal parameter value held in the
IPR list. A range is listed when two numbers have been specified, or
the whole list is case of no range specification. New values may be
assigned with the SET IPR instruction.
Example: LIST IPR 3 5
MONO (PERSP d)
A single perspective drawing is to be produced as seen
from a point at d cm. along the ZP axis, above the centre of the
drawing. The default setting is 10000 cm. (effectively infinity) but
may be set to 60 cm. for convenient perspective viewing. The actual
value is plotted in the top right corner of the plot (zero for infinite
perspective) to avoid confusion.
NOMOVE
Nomove toggle.
NOSORT
No atom list sorting toggle.
OMIT OUTSIDE (xmin xmax ymin ymax zmin zmax/atom-name
r/0)
All atoms with their centres outside the box defined by
the fractional coordinates xmin,...,zmax are omitted from the drawing,
together with any bonds to them. This is useful as a 'window' on a
packing diagram. The window may be reset by another OMIT OUTSIDE
instruction, or cancelled alltogether by OMIT OUTSIDE 0. Note that
molecules lying across the edge of the window will be drawn incomplete.
An alternative option is the exclusion of all atoms with their centres
outside a sphere with radius r around a specified atom.
Example: OMIT OUTSIDE C(1) 5
OMIT OUTSIDE 0.5 1 0.5 1 -.25 .25
OMIT aru .../resd
Omit the specified items from the 'plot-list'.
ORGA
Set default parameters for type organic structure.
OVERLAP (MARGIN mrg[0.10]) (SHADOW
shad[0.10])(ON/OFF)/BA/BB[ON]
The overlap margin (non-bonded bond-bond, atom-atom,
atom-bond overlap) is set by default to the value mrg = 0.1 cm and the
incoming bond shadow margin to shad = 0 cm. Overlap calculations (by
default) may be turned off for fast testruns. This should be specified
before plotting and after the specification of the plot-style.
Example: OVERLAP OFF
PACK (RANGE xmin xmax ymin ymax zmin zmax (atom-name))
This causes a search for all ARU's having their centres
inside the box defined by the fractional coordinates given. By default
PACK RANGE displays the contents of a unit cell. However, this will not
show the complete packing arrangement of the crystal; it is necessary
to supply a range that will ensure that a pair of translated molecules
will be found in each axial direction. This is achieved by giving a
range of cell translations. In most structures, the result of a range
of two in each axis is usually too congested to be of any use, so that
it is best to restrict the range to one on the axis closest to the view
direction.
e.g. PACK RANGE -0.5 1.5 -.5 1.5 0 1
might be appropriate for a z-axis projection. The
instruction PACK generates by default all ARU's with their centre
within the unit cell.
The ARU's that obey the conditions are added to the ARU
list. The ARU list is reset to ARU UNIQUE at the beginning of the
search. No other lists are affected. The ARU list may be displayed by
the LIST ARU instruction.
PACK PLAN h k l d1 d2 RANGE xmin .. zmax (atom_name)
ARU's are put in the moles list that satisfy the
condition of lying within the range xmin,...,zmax and in the
neighborhood of the specified hkl-plane (d1 and d2 are in Angstrom).
Example: PACK PLAN 1 1 1 -.5 .5 RANGE -1 2 -1 2 -1 2
PLOT (DISPLAY/META) (LIST) (MOGLI)
This produces a drawing using the information set up by
the previous instructions on either the current graphics medium
(default) or on the specified medium (Display, Plotter or Meta- file).
The default medium is either the one previously set or the display by
default. An automatic JOIN RADII UNIQUE EXPAND instruction is executed
when no previous JOIN instruction was given and a VIEW MIN instruction
is case of no previously given VIEW instruction. The MOGLI option may
be used to generate DGE and OBY files to be used to view the molecule
in 3D with the PSSHOW program of the MOGLI package on a PS300 display
(use PLOT CAL MOGLI to generate the files without display or plotter
output).
The special instruction PLOT CAL 3 will generate a file
with full 3D vector information for a ROD-style plot, independent of
previous parameter settings.
PUT atom-name/atom-type/OR/OA/OB/OC position
(atom-name/atom-type/OR/OA/OB/OC position .. )
position: N, NE, E, SE, S, SW, W, NW, NUCL, AUTO
The automatic label positioning routine considers eight
(or nine in the case of SOLID NUCL) possible positions for each label.
These are conveniently designated by the compass directions N, NE, E,
SE, S, SW, W, NW (or NU). The PUT instruction forces particular atom
labels into positions chosen explicitly by the user. Atoms named here
are positioned first, then the automatic routine places the rest. A
position may also be given as AUTO, so that all atoms of a given type
can be fixed and then specific exceptions made:
Example: PUT C SE C12 W C14 AUTO
PUT instructions must follow LABEL. They will be ignored
if they precede it.
QUIT
This gives immediate exit from the program.
RADII ATOMS COVALENT/CPK/AUTO/ALL r
This globally sets the atomic radii (Angstrom) for
the plotting of the spheres in the SOLID, ROD and CPK style. The
appropriate instruction is normally executed automatically. In the
SOLID and ROD mode spheres are drawn at 0.5 times their covalent radius
and in the CPK mode at the covalent radius + 0.8.
RADII ATOMS atom-type1 r1 (atom-type2 r2 (...) )
This instruction may be used to input user defined
radii for the spheres to be drawn. The actual values may be listed with
a LIST TYPES instruction.
RADII BONDS (DASH) ALL r n
Bonds in SOLID or ROD drawings have cylindrical
radius r Angstrom (default 0.04 and 0.2 resp.) and are drawn with n
(default n = 8) lines along the circumference of the cylinder, spaces
(180/(n+1)) degrees apart on the visible side of the cylinder. This
instruction resets r and n for all bonds.
RADII BONDS (DASH) TO atom-name/atom-type r n
This sets r and n for all bonds to a particular
atom or atom type. This may be useful to emphasize coordination of a
particular atom. To produce single-line bonds, set r - 0 and n = 1.
Bonds with n = 0 are omitted.
RADII BONDS (DASH) atom-name1 atom-name2 r n
This sets r and n for a particular bond already in
the connection list.
RADII BONDS (DASH) INTER/NORMAL r n
This sets r and n for all intermolecular bonds
created by a JOIN RADII INTER instruction. This is useful, for example,
in distinguishing hydrogen bonds.
RADII BONDS ALL not only resets r and n for all
bonds, but also cancels all other RADII BONDS instructions which have
already been given, i.e. 'all' really means all. To reset r and n for
all bonds EXCEPT special ones, use this instruction instead.
When the program is drawing the bonds, it looks
though the list of the RADII BONDS instructions and assigns the r and n
values of the last instruction given which is relevant to the bond
being drawn. In this way the result of conflicting instructions can be
controlled by the order in which the data card are given. An example of
such a list of instructions:
RADII BONDS ALL 0.05 5
RADII BONDS INTER 0.02 2
RADII BONDS TO CU1 0 1
RADII BONDS TO NA 0.03 2
RADII BONDS CU1 O4 0.06 10
Note, however, that if a particular RADII BONDS
instruction is given a second time with different values of r and n,
this resets r and n without altering the order of the RADII BONDS
instructions. E.g., the sequence
RADII BONDS TO H 0.02 4
RADII BONDS INTER 0 1
RADII BONDS TO H 0.03 7
is equivalent to
RADII BONDS TO H 0.03 7
RADII BONDS INTER 0 1
i.e. the second RADII BONDS TO H instruction
directly replaces the first.
RADII BONDS TAPER t
In order to enhance the perspective effect of
drawings (see MONO and STEREO options), bonds are drawn with an
exaggerated taper, the degree of exaggeration being set by the
parameter t. t = 1 gives maximum exaggeration. The default setting is
0.375. Tapering is applied even if the viewing distance is effectively
infinite, unless t = 0.
RENAME at1 at2 (at3 at4 (...))
RESET
Before any plotting instructions are read, various
default parameters for plotting must be set. This is automatically done
at the beginning of the program, but can also be done at any time by
use of RESET.
RETRACE LABELS (n (d))
Labels are retraced n times.
ROD (NUCL/SHADE (a1 a2 (d))/GLOBE/NET (nh
nv)/CONTOUR/SEGMENT/ DOTS/BWCOL/BLACK/CROSS/PARAL/MERID)/(COLOR (a1 a2
(d))) (SPOT)
This prepares for a ROD-style plot with atoms optionally
shaded, coloured, drawn with a net or contoured surface or individually
characterized (see CPK for further information).
SAVE (AUTO)
This instruction may be used to save instructions to be
used on other data sets as well. This feature is useful when examining
a series of structures taken from the crystallographic data base. All
instructions following a SAVE instruction until an END are saved.
SEGMENT (plotstep (substep))
Plotstep and substep are parameters that determine
the accuracy of the plot, the speed and the computing time needed for
the plot. Testing for overlap is done in steps of size plotstep. When a
problem is encountered the testing will be redone in steps of size
plotstep/substep. The default values are 0.1 cm and 4 steps
respectively. For accurate plots, in particular on either the plotter
or the meta-file, values of 0.01 cm and 1 are recommended for the above
parameters.
SET (IPR/PAR) nr val
This instruction is not meant for general use. It
provides a facility to modify internal parameters, in particular those
with no equivalent (sub)keyword.
SIZE sz (SCALE sc) (CHAR ch) (TITLE ti)
The default character size (ch = 0.4 cm) may be
changed with a SIZE 0 CHAR ch instruction. Similarly, the default
character size of the title (ti = 0.5 cm) may be changed with the TITLE
sub-keyword: SIZE 0 TITL ti. The other option are not effective as yet.
SOLID (NUCL/SHADE (a1 a2 (d))/COLOR (a1 a2 (d))/NET
(nh nv)/ GLOBE/SEGMENT/CONTOUR/SEGM/DOTS/BWCOL/CROSS/PARAL/MERID)
(SPOT)
This gives a PLUTO-type bond and stick plot. See the
CPK instruction for other keywords.
STEREO (SMALL) (RG/GR/RB/BR/CROSSED) (PERSP d)
This produces a stereo pair, as seen by an observer
with eye- separation of 6 cm. at a distance d ( default 60) cm along
the ZP axis. If the keywords RG or GR are present, the left-eye and
right- eye views are superimposed instead of being placed side-by-side,
but are drawn in different colors, so that the stereo effect can be
observed using appropriate red/green or green/red filters. The sub-
keyword CROSSED allows for crossed eye vision.
STICK (COLOR)
This asks for a stick model drawing, i.e. one in which
the atoms are points and the bonds single lines. A succession of such
drawings requires very little computing and plotting time, and is
useful as a preliminary run for checkout and to find a good view
direction.
Note: since atoms are represented by points in this
presentation, as are bonds when viewed along their direction,
non-bonded atoms and some linear molecules viewed from the end are not
shown in STICK plots.
STRAW (NUCL/SHADE (a1 a2 (d))/COLOR (a1 a2 (d))/NET
(nh nv)/ GLOBE/SEGMENT/CONTOUR/SEGM/DOTS/BWCOL/CROSS/PARAL/MERID)
(SPOT)
STOP
This gives an immediate EXIT from the program.
TITL text
The title of the plot is normally taken from the TITL
card that preceded the coordinate data. It can be overruled with a new
TITL instruction.
TORSION atom-name1 atom-name2 atom-name3 atom-name4
The dihedral angle (not necessarily involving bonded
atoms) for the specified atoms is calculated as an aid to analyze the
geometry of the structure (exhaustive geometry listings may be obtained
with the companion program PLATON).
Example: TORSION C(2) O2 N(2) C(4)
UNITCELL (OFF/ON) (rbo nli)
This allows a unit cell outline to be drawn. The
outlines are treated as bonds. Their default setting is: rbo = 0.01 and
nli = 2
UNLABEL (atom-names/atom-types/ALL/(UNITCELL)
(ATOMS) (ARU))
This instruction may be used to unlabel. see LABEL.
A great variety of instructions is available for the
specification of the viewpoint. By default a minimum overlap
instruction is executed (i.e. projection on the molecular least squares
plane). Other instructions allow the view direction to be chosen by the
user in terms of crystal or orthogonal axes, in terms of molecular
features, by rotation about the plotting axes from a previously defined
view, by rotation about any other line or bond from a previously
defined view.
VIEW MIN (rotations)
This produces a minimum overlap view. The view is
perpendicular to the least-squares plane through the included atom set
as generated for the current ARU list. A VIEW MIN instruction is
executed automatically with a PLOT instruction when no previous VIEW
instruction was given.
Example: VIEW MIN XROT 45
VIEW UNIT (rotations)
This produces a view with XO along XP (horizontal)
and YO along YP (vertical), possibly modified with a sequence of
rotations.
A given orientation may be reconstructed, independent
from its history, using the three rotation values that are shown in the
lower right corner (xr), the upper left corner (yr) and the lower left
corner (zr) with the instruction:
Example: VIEW UNIT XROT xr YROT yr ZROT zr
VIEW is equivalent with VIEW UNIT.
VIEW CURRENT (rotations)
This instruction updates the current view matrix.
VIEW rotations is equivalent with VIEW CURRENT rotations.
Example: VIEW CURRENT XROT 45 ZROT -60
Note: XROT 45 is a shortcut equivalent for VIEW
CURRENT XROT 45
VIEW XO/YO/ZO (rotations)
View along one of the orthogonal axes towards the
origin.
VIEW AFACE/BFACE/CFACE (rotations)
For a view along the line from the point (1.0, 0.5,
0.5), (0.5, 1.0, 0.5) or (0.5, 0.5, 1.0) towards the origin (crystal
coordinates).
VIEW ALIGN atom-name1 atom-name2 (aru) WITH XP/YP
rotations
This causes an automatic ZROT sufficient to bring the
projection of the line between the two atoms parallel to the plotting
XP (YP) axis. A warning message is issued when the two atoms are
superimposed in the current view, so that this instruction is not
uniquely defined.
Example: VIEW ALIGN C1 C2 WITH YP
Note: to bring the vector between the atoms
atom_name1 and atom_name2 parallel to XP use the instruction VIEW LINE
atom_name1 atom_name2 YROT 90
VIEW DIRECTION x y z (rotations)
This defines a view along the line from the point
(x,y,z) towards the origin (crystal coordinates). This may be useful
for views down the crystal axes for non-orthogonal crystal systems.
VIEW LINE atom-name1 atom-name2 (rotations)
The direction of view is from the first atom to the
second.
VIEW BISECT atom-name1 atom-name2 atom-name3
(rotations)
The view is into the angle n1-n2-n3 with n2 deepest
in the plot.
VIEW PERP atom-name1 atom-name2 atom-name3
(rotations)
The view is perpendicular to the plane containing the
three atoms, seen from the side which makes a clockwise order of the
atoms in the plot n1-n2-n3.
VIEW INVERT (rotations)
An inverted image with respect to the current image
is obtained with this instruction.
VIEW MATRIX r11,r12, .. ,r33 (rotations)
This option allows direct input of the view rotation
matrix (by row), if it has been previously calculated by another
program. An error message will be produced by a matrix for which the
determinant is not within reasonable rounding errors of +/-1.
rotations:
(XROT xr)(YROT yr)(ZROT zr)(LROT lr x y z)
(OROT or x y z)(PROT pr x y z)
(BROT atom_name1 atom_name2 br)
Examples of VIEW instructions:
VIEW MIN
VIEW YO
VIEW AFACE ZROT 15
VIEW DIRECTION 0.25 0.25 1
VIEW LINE PT1 BR1
VIEW BISECT C1 C2 C3
VIEW PERP N1 CU1 N2
VIEW LINE C1 C2 ZROT 90 YROT -30
VIEW CURRENT BROT C1 C2 -45
The atomic parameters (including unit cell
parameters, symmetry and coordinates) for a given structure may be
entered in one of the following ways:
a - The STANDARD PARAMETER FILE Format (SPF).
b - SHELXL-97 and SHELXS-86 type Format
c - Simple Coordinate Format and Angstrom data
d - CIF-style (Restricted)
The SPF-file is card image oriented. The first four
characters on a card specify the nature of the data that follow on that
card. Data that are not needed for the current program are simply
skipped. All data are read free format. All input data are transformed
to upper case except the text on the TITL card.
Note: A card image may be continued on the next one
by putting an '=' sign on the one to be continued. This does not apply
for a TITL card.
TITL text
This text is used for various titleing purposes. It
may be overridden at any time by another TITL instruction. This card is
optional.
CELL (wavelength) a b c alpha beta gamma
Optional wavelength and cell parameters in Angstroms
and degrees respectively. No CELL card should be given when Angstrom
data input is intended (see ANGSTROM instruction). This card should
preceed any fractional coordinate data.
SPGR space-group-name
Space group symbol. See Appendix-III for more
details. Space group P1 is assumed when no symmetry is specified.
LATT (P/A/B/C/I/F/R (A/C))
First parameter specifies the Bravais lattice type
and the second whether the lattice is acentric or centric. See
Appendix-III for details.
SYMM symmetry-operation
See appendix-I for details.
ATOM atom_name x y z (pop) (sig(x) sig(y) sig(z))
(spop)
This specifies the positional parameters, the
population and their estimated standard deviations. The atom_name
should conform some rules in order to be acceptable since it is
interpreted. The first one or two characters should correspond to an
element name known to the program. The number of characters of the
element type and that of the attached digital number cannot exceed 4.
Acceptable labels are: Ag Zn(2) C(2A) Fe1b
Note: QW is equivalent to O and Q1 is equivalent to
C1.
TRNS (t11,t12,t13,t21,t22,t23,t31,t32,t33)
(sh1,sh2,sh3)
This optional instruction may be used to transform
the data to a new unit cell. The first nine data items are the elements
of the matrix that describes the transformation of the cell axes ( =
new axis in terms of old ones). The origin may be shifted over the
vector (sh1,sh2,sh3). Related matrices are used to transform the atomic
coordinates. The TRNS instruction should be given before any ATOM card
is read and before the CELL card when it is to be transformed as well.
The space group symmetry is not transformed and should apply to the
transformed data.
Most SHELX type files (possibly edited with TITL,
CELL, LATT, SYMM information will be acceptable as well. In any case
the atomic parameters should be preceded with an FVAR card since this
triggers the program to expect SHELX format input. An END card on a
SHELX file will be ignored. Possibly some simple file editing may be
necessary.
Files with just positional parameters, not preceded
by CELL and symmetry cards are understood to be angstrom data in a
carthesian system. Coordinate data may be preceded by an ANGSTROM card
with optionally a multiplication factor to transform the data to
angstrom units. This can be convenient when data originate from
quantumchemistry programs. Scaling the data to Angstrom scale will be
necessary to obtain connected sets with a PLOT instruction.
ATOM cards may be as: C1 1.123 1.456 1.789
CIF-DATA FORMAT
A restricted format CIF-DATA file (such as produced
by SHELXL-97) is acceptable.
Space group symmetry is handled in PLUTON with a
general space group symmetry management routine that permits the
specification of the symmetry either explicitly in terms of the general
equivalent positions as presented in the International Tables or
implicitly in terms of space group generators. The generators for all
space groups in their standard setting and some commonly used non-
standard settings are also implicitly retrievable by the program from
internal tables (see tables below) on the basis of the specified name
of the space group (e.g. R-3m)
EXAMPLE: The symmetry for space group nr. 19
(P212121) may be specified either as:
LATT P A
SYMM X,Y,Z
SYMM 1/2 + X, 1/2 - Y, -Z
SYMM -X, 1/2 + Y, 1/2 - Z
SYMM 1/2 - X, - Y, 1/2 + Z
or
LATT P A
SYMM 1/2 + X, 1/2 - Y, -Z
SYMM -X, 1/2 + Y, 1/2 - Z
or
SPGR P212121
or
SPGR P21 21 21
A LATT card should precede any SYMM card in order
that the symmetry arrays are initialized to either, by default, a
primitive non- centrosymmetric lattice or to the specified lattice type:
(P/A/B/C/I/F/R) and (A)Centric type (A/C).
The general equivalent positions should be given as
specified in International Tables and should have the centre of
symmetry at the origin, in the case that the space group is
centrosymmetric. The symmetry operation SYMM X,Y,Z is always implicitly
assumed as the first symmetry operation and needs not be given although
any redundancy in the symmetry input will be ignored.
Note: Rhombohedral lattice types (in hexagonal
setting) can be specified in two ways: Thus space group R3 may be
generated with:
LATT P A
SYMM -Y, X-Y, Z
SYMM 1/3+X, 2/3+Y, 2/3+Z
or
LATT R A
SYMM -Y, X-Y, Z
The same space group on rhombohedral axes should be
specified as R3r.
or
LATT P A
SYMM Y,Z,X
The translation part may be specified either as a
ratio or as a real (e.g. 1/4 or 0.25).
Monoclinic-b is taken as the standard setting for
monoclinic space groups. Other settings are to be specified by the full
space group name: e.g. P112 for the monoclinic-c setting of P2.
Non-standard orthorhombic settings such as space
group A2aa may be handled by specifying Ccc2.-cba on the SPGR card (see
International Tables Vol A). In fact the program automatically modifies
the input line accordingly for non-standard settings (see table below).
The standard setting symmetry is than transformed accordingly.
Note: Symmetry may also be presented in the SHELX-76
style. However a LATT card should always be supplied since the default
symmetry of PLUTON is always P1 whereas SHELX defaults to P-1.
For compatibality reasons with other programs, a
space group name such as P41212 may also be specified as P 41 21 2.
21-09-98